Service Hotline:

+8615920011166

en en

Advertising machine

Current location: Home > News > Product News > Advertising machine

Indoor wall hanging advertising machine installation method indoor engineering construction specification guide

Release date: 2026-10-31 Clicks:0

01First, clarify the boundary of responsibility: what Qunmao provides and what it does not provide.

Before discussing any technical details, one thing needs to be made clear:Conventional wall-mounted advertising machine installationInvolving hardware supply and on-site construction of two links, Qunmao's role is the former. In overseas engineering projects, the most common communication cost encountered by the purchaser is not that the product parameters are not clear, but that the responsibilities between the supplier and the installer are vague and the problems are shirking each other. Put the boundaries forward, both responsible for the customer, but also the key to improve project efficiency.

Qunmao provides

  • Advertising machine hardware and supporting rack selection recommendations
  • Product specification, outline dimension drawing, VESA hole spacing parameters
  • Installation manual, installation diagram and multilingual technical data
  • Factory pre-commissioning and batch project software pre-configuration
  • CMS docking data and remote video technical guidance
  • Quality assurance and after-sales response support

Qunmao not available

  • Site door-to-door survey and wall structure assessment
  • On-site construction of wall drilling and hanger fixing
  • Strong and weak current wiring construction and electrical transformation
  • Local building, electrical and fire regulations declaration agency
Reading instructions:This document is an installation specification, inspection points and acceptance reference to help the purchaser and integrator understand the engineering standards, not a substitute for the specific construction plan of the local licensed installation team. All field work shall be carried out by local qualified professionals in accordance with local regulations.

Some overseas customers need to know before purchasing.Commercial Parameters and Engineering Customization Scheme of Conventional Wall Hanging Advertising Machine, can be combined with the reference of this article.

02Installation method selection: wall bracket type and embedded

There are two main types of indoor advertising machine installation: wall-mounted bracket and embedded. There are essential differences between the two in the construction logic, pre-conditions and maintenance methods, and the selection stage must be judged.

Wall-mounted bracket

The most common indoor installation scheme. The equipment is fixed on the wall rack through the VESA standard interface, and the construction is relatively mature. It is suitable for most retail stores, hotel lobbies, corporate office areas, government halls and other scenarios. The equipment can be removed as a whole during later maintenance, and the maintenance and replacement efficiency is high.

Embedded

Insert the device into the wall or decorative surface, and the screen surface is flush with the wall surface. Visual integrity is better, suitable for elevator hall, high-end commercial space, brand flagship store and other high aesthetic requirements of the scene. However, the embedded system requires high coordination of civil works in the early stage. It is necessary to confirm the size of the opening, the location of the heat dissipation air duct and the access opening in the decoration design stage. Once the wall is completed, the cost of rebuilding is very high.

Comparison of the two schemes

Comparison dimension Wall-mounted bracket Embedded
construction complexity Medium, standard rack mount Higher, need to cooperate with civil works
Pre-conditions The wall load can reach the standard Opening, cooling, and maintenance space must be reserved.
Aesthetics Equipment exposed, clear lines Flush with the wall, strong overall feeling
Cooling method Natural convection, plenty of space Special cooling air duct shall be designed
Ease of maintenance Can be removed as a whole, easy to maintain It is necessary to reserve an access port, and the maintenance space is limited.
Applicable scenarios Retail, office, hotel, government Elevator lobby, high-end commerce, brand showrooms

This article focuses onConventional wall-mounted advertising machine installationEmbedded only as a selection reference. The wall-mounted machine adopts the standard VESA mounting interface, and can be equipped with fixed, adjustable angle or rack with front maintenance function. Special attention should be paid to the fact that the VESA hole spacing and the weight of the whole machine must match the rated load of the hanger at the same time-only the hole spacing is not the load bearing, or only the load bearing is not the hole spacing, which is a common hidden danger in the selection stage.

03Site survey and confirmation of installation conditions

Site survey is the link with the highest input-output ratio in the whole installation process. The survey phase takes an additional two hours, which may avoid two days of rework during site construction. The following inspection items are recommended to be confirmed by the purchaser or integrator before the equipment arrives.

Wall type and load-bearing capacity

The carrying capacity of different walls on wall-mounted advertising machines varies greatly, and cannot be judged only by "looking strong. Concrete walls and solid brick walls can usually be installed directly, but lightweight structures such as light steel keel gypsum board walls, hollow brick walls, and glass curtain walls require special evaluation of reinforcement plans. The gypsum board wall itself has limited load-bearing capacity, so it is not suitable to directly fix heavy objects. The recommended method is to find the wooden keel or metal keel behind and fix the hanger to the keel position. If the keel position cannot be confirmed, special gypsum board anchor bolts are required, but the load-bearing capacity is still limited. This scheme is not recommended for large-size equipment. For models above 65 inches, it is recommended to use metal expansion bolts for fixing.

Matching of equipment and hanger

  • Weight of the whole machine and bearing of the rack:The rated bearing of the pylon shall be left with a safety margin, and the actual weight recommended for commercial projects shall not exceed 70% of the nominal bearing of the pylon.
  • VESA Pitch:Common specifications include 100 × 100, 200 × 200, 400 × 400, 600 × 400, etc., which should completely correspond to the installation holes on the back of the equipment.
  • Overhaul space:Adequate heat dissipation clearance and cable operation space shall be reserved between the equipment and the wall surface. The front maintenance rack has low requirements for side space.

Installation Environment Confirmation

  • Visual height and viewing distance:The wall-mounted machine is suitable for close viewing scenes within 3 meters, and the installation height is usually so that the center line of the screen is level with the adult's standing sight
  • Lighting conditions:Avoid direct sunlight on the screen, window or high lighting environment, it is recommended to choose a brightness model above 400 cd/㎡.
  • Ventilation and heat dissipation:Heat dissipation space shall be reserved around the equipment to avoid the influence of closed decorative cover on heat dissipation.
  • Public Area Demolition:Public scenes such as shopping malls and stations need to consider hanger locking and cable anti-pull design.

Electrical and network conditions

  • Voltage and plug:Overseas projects need to confirm the local voltage standard (110V / 220V / 240V) and plug system (European standard/American standard/British standard/Australian standard), and the equipment should support 100-240V wide voltage input.
  • Power circuit:Confirm whether there is available power supply near the equipment installation position, otherwise, it is necessary to evaluate the wiring trough scheme.
  • Network coverage:Wired network access point location, Wi-Fi signal strength, 4G/5G module required
  • Strong and weak current separation:Signal lines and power lines shall be laid separately to avoid electromagnetic interference.
Gunmao Support:Product specifications, dimensional drawings, VESA parameters, machine weight data and Site Survey List can be provided to help customers complete feasibility assessment during the procurement phase. For detailed parameters of the wall-mounted machine, you can view55 inch wall-mounted digital advertising machine product page。

04Wall-mounted fixed construction steps and specification inspection

Wall hanging advertising machine constructionThe core is not "how to drill", but "what is the inspection standard for each step". The following step overview helps the purchaser and integrator understand the construction process, which is performed by the local certified installation team.

Overview of construction steps

  1. Confirm installation point and elevation:Determine the position of the center line of the screen according to the viewing distance and line of sight, and use a spirit level to mark the installation reference line of the hanger
  2. Check the weight of the rack, VESA and equipment:After unpacking, confirm that the hanger model and VESA hole spacing are consistent with the equipment parameters, and the load bearing of the hanger is sufficient.
  3. Confirm the wall reinforcement scheme:According to the wall type to determine the fixed way. Concrete and brick walls can use expansion bolts; gypsum board walls need to confirm the keel position or use penetration reinforcement; hollow walls need to evaluate special anchoring schemes
  4. Fixed rack:Install according to the fixing points and fastening requirements specified by the hanger manufacturer. The specific bolt specification and torque value shall be determined by the local installation team according to the pylon requirements and local specifications.
  5. Equipment on wall:It is recommended that two people work together and use suction cup auxiliary tools for large-size equipment. Ensure that the equipment is fully engaged with the hanger clip
  6. Adjust the level and lock:Use a spirit level to confirm the level of the equipment, and lock all adjusting screws and anti-off devices.
  7. Connect the cable and do the anti-pull treatment:After the power line and signal line are connected, use a line card or tie to fix it to avoid pulling the interface by the weight of the cable.

Common rack form

  • Fixed rack:The equipment is attached to the wall, the structure is the simplest, the load-bearing stability is the best, and it is suitable for scenes that do not need to adjust the angle frequently.
  • Adjustable angle hanger:Support up and down pitch or left and right rotation adjustment, suitable for scenes that need to adjust the screen angle according to the viewing position
  • Forward maintenance rack:The equipment can be pulled out or turned over forward, which is convenient for wiring and maintenance, and is suitable for scenes where the equipment is installed on the wall and there is no operating space on the side.

Treatment ideas for different walls

Wall type Feasibility judgment Proposed plan
Concrete/solid brick wall Sufficient load-bearing, can be installed directly Use metal expansion bolts to fix according to the hole position of the hanger
Light steel keel gypsum board wall Not directly load-bearing Find the keel position and fix it, or install a backboard/reinforcement structure.
Hollow brick wall To be assessed Use chemical anchor bolts or special hollow wall anchors, if necessary, through the back plate
Glass curtain wall/decorative surface Usually not directly fixed It is necessary to embed connectors in the structural layer, or use floor support scheme instead.
Safety Tip:The reinforcement scheme of the light wall can not be judged by the weight of the equipment alone. The local load-bearing capacity of a gypsum board wall is affected by multiple factors such as keel spacing, plate thickness, installation method, etc., and must be determined after on-site evaluation by the local installation team. Qunmao can provide hanger recommendations, load-bearing parameters and installation diagrams, but the wall reinforcement plan should be designed by local professionals.

Qunmao wall-mounted advertising machine adopts standard VESA installation interface, which can be adapted to mainstream rack products in the market, and can also provide matching rack selection suggestions according to project requirements. When choosing a rack, VESA hole spacing and load bearing are two parameters that must be checked at the same time.

05Hidden wiring process and wiring specification

Wiring SpecificationIs easy to be underestimated in the installation of indoor advertising machine. Cable go well, short-term look beautiful, long-term stability and maintenance efficiency. In overseas projects, wiring also involves local electrical regulations and wire standards, which need to be planned in advance.

Wiring Principles

  • Strong and weak current separation:The power line and network cable, HDMI/DP and other signal lines should be laid in charge or in separate slots to avoid flickering and signal interruption caused by electromagnetic interference.
  • Cable classification planning:The power line, network line, audio and video signal line and control line are marked separately for later investigation.
  • Reserved redundancy:Appropriate lengths are reserved for cables at the equipment end and the power distribution end to facilitate later maintenance and adjustment.

Common routing methods

Route mode Applicable scenarios Precautions
Buried in the wall Synchronous construction in decoration stage Threading pipe protection is required, and the thickness of protective layer of fire circuit pipe shall not be less than 30mm.
Metal cable tray Decorated wall or surface-mounted scene The trunking shall be firmly fixed, and fire blocking shall be done at the crossing fire compartment.
decorative trunking Commercial space with appearance requirements Select the trunking close to the wall color to keep the visual neatness
Equipment back line management When the clearance between the hanger and the wall surface is sufficient Use cable management rack or cable tie to fix, avoid cable squeezing and pulling

Wiring Points for Attention in Overseas Projects

  • Wire standard difference:Different countries have different standards for the cross-sectional area, insulation grade and flame retardant requirements of the power cord, and the wire rod should be confirmed and selected by the local electrician.
  • Plugs and sockets:According to the standard configuration of the destination country, European standard (Schuko), American standard (NEMA), British standard (BS), etc. can not be mixed
  • Grounding requirements:Commercial display equipment should ensure reliable grounding, which is mandatory in some markets
  • Labels and documents:Both ends of the cable shall have clear labels, and the maintenance length shall be reserved to facilitate later maintenance and expansion.
Gunmao Support:Equipment interface layout, back wiring structure description and cable type suggestions can be provided to facilitate integrators to complete wiring design before construction.

06Power-on, networking and system commissioning

Installation and debugging of indoor advertising machineThe quality of the equipment directly determines the operational efficiency after delivery. The goal of the debugging phase is not only to "be able to start up", but to ensure that the equipment runs stably in the network environment, the CMS system is normally docked, and batch equipment can be managed in a unified way.

Check before power-on

  • Power supply specifications:Confirm that the input voltage matches the local power grid and the equipment is grounded reliably
  • Cable connection:Power line, network cable and signal line shall be firmly connected without looseness or exposure
  • Fixing of equipment:Confirm that the equipment is fully engaged with the hanger and the locking device is in place.
  • Heat dissipation space:There is no shelter around the equipment, and the vent is not closed

Networking mode selection

Networking method Applicable scenarios Advantages and limitations
Wired network Fixed point, high requirements for stability Stable connection, sufficient bandwidth, pre-wiring required
Wi-Fi Difficult wiring or temporary deployment Flexible deployment, signal coverage and stability need to be confirmed
4G / 5G module Outdoor or temporary points without fixed network Independent networking, considering traffic cost and signal coverage

Key points of system debugging

  • Display parameters:Confirm that the resolution output matches the native resolution of the screen, and the brightness and color temperature are adjusted according to the scene
  • Playback Settings:Timing switch, volume, playlist configuration
  • Network connection:Confirm that the device obtains the IP address, DNS resolution is normal, and can access the CMS server
  • CMS docking:Device registration, group configuration, content publishing test, remote management function verification
  • Batch Items:Multiple devices can be pre-installed systems, pre-configured network parameters or CMS accounts, reducing on-site commissioning time

Qunmao can provide pre-commissioning and basic parameter pre-configuration services for batch projects. CMS registration and content distribution can be completed after the equipment is connected to the network. For a practical application of the CMS remote management function, referWall-mounted commercial advertising machine selection guide。

07Engineering Acceptance Criteria

Acceptance is the last hurdle of project delivery and the key node of responsibility division. It is recommended to check item by item according to the following dimensions, and record the acceptance results in written form for later traceability.

Appearance and structure acceptance

  • The screen has no scratches, no bad points, and the frame has no deformation.
  • The equipment shall be installed horizontally without inclination or looseness.
  • The hanger is firmly fixed, and the locking device is in place
  • Cable arrangement specification, no nudity, no pulling
  • Adequate maintenance space, does not affect the later maintenance

Electrical and functional acceptance

  • Normal power supply, reliable grounding and no abnormal heating
  • Compliance with local electrical safety code requirements
  • Normal startup, no abnormal noise or picture problem
  • Network is normal, CMS remote management function is available
  • Content playback test passed, touch or external device functions normally (if configured)

Aging Test Recommendations

It is recommended to conduct continuous operation tests for batch projects before acceptance, usually 24-72 hours, to observe equipment fever, crash, black screen, network interruption and other problems. Qunmao advertising machine supports 7 × 24 hours of continuous operation, and has passed the aging test before leaving the factory. On-site aging tests verify the stability of the equipment in the actual installation environment.

Acceptance Document List

  • Installation photos (including hanger fixing, equipment on wall and cable routing)
  • Equipment serial number record
  • Network configuration information (IP address, CMS account)
  • Acceptance Checklist Signed

08Common Installation Issues and Mitigation Recommendations

Most of the following problems can be avoided through the preliminary survey and confirmation of the selection stage. The purchaser and integrator check item by item before the project starts, which can significantly reduce the probability of on-site rework.

Frequently Asked Questions Possible causes Avoidance advice
Tilt or loose after installation Insufficient bearing capacity of wall, mismatch between hanger and equipment, insufficient fixing point Check wall type, hanger bearing and VESA parameters during survey
Gypsum wall can not be directly load-bearing Limited local load-bearing of lightweight wall Confirm the keel position, or install backboard/reinforcement structure, and use other schemes for large-size equipment.
Equipment heating is obvious Insufficient cooling space, high ambient temperature, and prolonged operation at high brightness. Reserved ventilation space, reasonable setting of brightness and timing switch machine
The picture signal is unstable Cable too long, strong and weak current interference, interface loose Standard wiring, strong and weak current separation, selection of appropriate wire and length
Unable to network or manage remotely Network policy restrictions, IP configuration errors, weak Wi-Fi signals Confirm network permissions, IP and CMS connections during debugging phase
Post-maintenance difficulties The equipment is too close to the wall, there is no operation space on the side, and there is no access port. Select front maintenance hanger or reserve sufficient maintenance distance

09Overseas Project Case Reference

The following two cases show the collaboration and delivery process of Qunmao in different types of overseas projects, focusing on the cooperation mode between hardware supply, remote technical guidance and local installation team.

A
Digital Display Project of Southeast Asian Chain Retail Stores
Retail chain · batch delivery · multi-store unified management

Project Background

The customer is a chain retail brand in Southeast Asia, and advertising machines need to be deployed at the back wall and shelf end of the cashier area of multiple stores for promotional information display and brand image unification. The project requires unified management of multi-store content, headquarters can be updated remotely, and stores can adjust some promotional content locally.

Qunmao Collaboration Mode

Qunmao provides 43-inch and 55-inch wall-mounted advertising machine hardware, and completes system pre-installation and CMS account pre-configuration before leaving the factory. VESA parameters, rack selection suggestions and installation diagrams were provided to the customer, and the local integrator team completed the wall fixing and wiring construction. In the debugging phase, CMS docking and device grouping configuration are completed through remote video guidance.

Project Results

Multi-store equipment access to the same CMS platform, headquarters unified release content, stores can adjust the local promotional information within the scope of authorization. The equipment supports 7 × 24-hour operation and is suitable for all-weather business scenarios of stores.

B
European Hotel Lobby Information Publishing System Project
Hotel hospitality · Multi-language content · High-end customization

Project Background

The client is a European hotel group and needs to deploy information release screens in the lobby, conference center corridor and elevator hall for welcome information, meeting scheduling, hotel service guidelines and multi-language announcements. The project has certain requirements for the appearance of the equipment, and it is hoped that the screen will be in harmony with the interior decoration style.

Qunmao Collaboration Mode

Qunmao offers a 55-inch wall-mounted advertising machine with a customized narrow bezel appearance to match the hotel's decoration style. Provide multilingual CMS operation data and content partition suggestions for multilingual content requirements. The European voltage is 220-240V, and the equipment supports wide voltage input to adapt to the local power grid. The wall hanging construction of the lobby and corridor points is completed by the local installation team. Qunmao provides the load-bearing parameters and installation schematic diagram of the hanger as a reference for construction.

Project Results

After the equipment is deployed, it is connected to the hotel content management system and different content is pushed by region and time period. Meeting scheduling and floor guidance were updated in real time, and the number of front desk inquiries decreased. The technical information provided by Qunmao in both Chinese and English reduces the cost of understanding for the local team.

For more information on how Qunmao advertising machines land in more indoor commercial scenarios, seeFive types of indoor commercial landing solutions。

10FAQ Frequently Asked Questions

wall advertising machine installation height how many suitable?
It is usually recommended that the center line of the screen be flush with the adult's standing sight, about 1.2-1.5 meters from the ground. The specific height needs to be adjusted according to the viewing distance and the scene: the close-up view (such as the back wall of the cash register) can be slightly higher, and the long-distance view (such as the end of the corridor) can be appropriately lowered.
gypsum board wall can install wall hanging advertising machine?
Gypsum board walls cannot be directly load-bearing. It is necessary to find the keel position in the wall and fix the rack on the keel. Or install a backboard for structural reinforcement. If the keel position cannot be confirmed and the equipment size is large, it is recommended to use other installation schemes or choose lightweight equipment.
wall hanging and embedded how to choose?
Wall-mounted construction is mature and easy to maintain, suitable for most indoor scenes. The embedded beauty is higher, but it is necessary to plan the opening, heat dissipation and inspection port simultaneously in the decoration design stage, and the later transformation cost is high. It is recommended to determine the installation method at the project design stage.
Do you offer on-site installation services?
Qunmao does not provide on-site installation and construction. We provide hardware, specifications, installation manuals and remote technical guidance. Site construction is recommended to be carried out by the local certified installation team, system integrator or engineering contractor and to comply with local architectural, electrical and fire codes.
How to adapt the voltage and plug of overseas projects?
Qunmao advertising machine supports 100-240V wide voltage input, which can be adapted to the power grid of most countries and regions. The plug system can be configured according to the destination country (European standard, American standard, British standard, Australian standard, etc.). The specific wire and distribution scheme shall be confirmed by the local electrician in accordance with the local electrical code.
Can batch projects be pre-configured with CMS and network parameters?
Sure. Qunmao supports factory pre-debugging and batch project software pre-configuration, including system pre-installation, network parameter preset, and CMS account pre-registration. After the equipment arrives at the scene, the registration and content distribution can be completed by accessing the network, thus reducing the on-site debugging time.

11Obtain technical information and project quotation

The key to the installation of conventional wall-mounted advertising machines lies in the preliminary survey, the matching of the hanger and the wall, the standardized wiring, the complete debugging and the clear acceptance. If you are planning an indoor advertising machine project, please contact Qunmao to obtain product specifications, installation size drawings and batch project quotations.

Service Hotline:+86 13714317162

Previous:Advantages of Conventional Wall-mounted Advertising Machines: Difference from Traditional Light Boxes and Analysis of Commercial Upgrade-Qunmao

Return to list

Next article:Elevator Advertising Machine Parameters Specifications Overseas Engineering Procurement Selection Standards and Configuration List