From the hierarchical networking of the head office/branch/sub-branch, the double-person rules of ATM banknote adding room and vault, the GPS and on-board video access of cash transport vehicles, the three-level response of alarm review, the compliance of financial private network, to the reverse of screen number, drill acceptance and customization capability of source manufacturers, the landing judgment of the monitoring splicing screen of bank outlets is given.
The most expensive mistake of the bank network monitoring splicing screen scheme is not that the screen is expensive, but that it is "putHospital Splice Screen SchemeChange the title and send it to the bank ".The front-end systems of banks and hospitals, communities and discerning projects look similar-all have video, access control and alarm, but banks have three types of hard constraints that are not available in scenes:Head Office-Branch-Sub-Branch-Network is a four-level structure.The screen wall is mainly located in the centralized monitoring center of the branch and the head office, and the network itself usually does not have an independent monitoring room;ATM banknote room and vault involve financial security, video, access control, access records must be linked according to the "double double lock" rule display;The armored vehicle is a moving targetThe access logic of GPS location and car video is completely different from fixed monitoring. In addition, the bank alarm is usually not "handled by the network itself", but a three-level response of "network alarm → branch review → head office confirmation → notification to the public security". What the screen wall displays in this process, who operates it, and how the authority is divided, determines whether the screen is "useful" or "decoration". This article is carried out in the order of "four-level architecture → bank-specific system → hierarchical networking → alarm review → screen number backstepping → site conditions → drill acceptance" and explainsQunmao Display Technology as a Source Manufacturer of LCD Spliced Screen in China in Bank Video Surveillance ProjectActual value in patchwork combinations, non-standard supports and long-term spare parts.
Four Essential Differences between 1. Bank and Hospital, Community and Snow Project
Bank security overlaps with the front-end systems of hospitals, smart communities, and discerning projects, but the organizational structure, core business, and compliance requirements are completely different. The first step in program design is to distinguish these differences.
| Dimension | Hospital Security | Smart Community | Bank Security |
|---|---|---|---|
| Organizational structure | Single hospital area, led by security department | Single or multi-community, property-led | Head Office-Branch-Sub-Branch-Network Level 4, led by security department and coordinated by science and technology department |
| Screen Wall Location | Hospital monitoring room | Community monitoring room | Mainly in the branch and head office centralized monitoring center, the network usually does not have an independent monitoring room. |
| Core business | Doctor-patient disputes, fire protection, and authority of key areas | Access Control Parking Perimeter | Alarm review, ATM cash room and vault double rules, cash transport vehicle monitoring |
| Alarm Response | Public security linkage in hospital disposal | Property Disposal | Network alarm → branch review → head office confirmation → public security linkage, three-level response |
| Network and Compliance | Hospital Intranet Security Special Network | Property Network | Financial private network, and public security networking needs to comply with the Ministry of Public Security, the Bank of China Insurance Regulatory Commission regulations. |
The core of the hospital program is "dispute resolution fire linkage key area authority", the core of the community is "access parking perimeter", the core of the bank is"Level 4 Graded Networking ATM Vault Double Person Rules Cash Transport Vehicle Monitoring Level 3 Alarm Review". The "doctor-patient dispute", "operating room authority" of the hospital template and the "unit entrance guard" of the community template are not only unprofessional, but may also be questioned by the security department and the science and technology department during the acceptance.
2. bank-specific systems: ATM, vault, cash truck, three links not available in other scenarios
The core of bank security, which is different from other scenes, is the monitoring object of ATM, vault and cash truck. Their access methods, linkage rules and permission requirements are completely different from ordinary video surveillance.
| System | Typical sources | Access mode | Screen wall linkage requirements | under what conditions |
|---|---|---|---|---|
| ATM equipment and banknote room | ATM vendor platform, bank core system, banknote room access control | ATM status is accessed through the manufacturer's platform or core system interface; video and access control in the banknote adding room are accessed through the security platform. | When the ATM is abnormal (such as vibration, prying, card money) alarm, pop up the ATM and the money adding room video, access control records | ATM manufacturers open state interface; The entrance guard and video in the banknote adding room have been linked. |
| Vault | vault access control, vault video, double access record | Vault access and video access via security platform; access records via access control system | When the vault door is opened, display double access information, vault inside and outside video, time record | vault access control supports double-person rule; video covers inside and outside the vault; records can be linked |
| Cash-in-transit vehicle | Vehicle GPS, vehicle video, escort system | GPS and car video are transmitted back to the branch/head office platform via wireless network. | Display the location of the cash transport vehicle on the GIS; access to on-board video; abnormal alarms (e. g. off-route, long stay) pop up | On-board equipment supports real-time backhaul; branch/head office platform supports mobile target access |
The vault and the banknote room usually require "double lock, double access". The screen wall side should be able to display: the name and photo of the current personnel entering and leaving, the entry time, whether the two people are all present, and the access control opening record. If only one person enters or the time difference between the two people exceeds the regulations, the system should alarm and pop up on the screen.This linkage relies on the two-person rule configuration of the access control system and the association of video, not the screen function. The plan should specify "who configures the access control rules, who does the video association, and what is displayed on the screen wall".
3. Level 4 Hierarchical Networking: How to Gather Videos of Head Office, Branch, Sub-branch and Network
The organizational structure of the bank is "head office-branch-branch-branch" four levels. The screen wall is mainly located in the centralized monitoring center of the branch and the head office. The network itself usually only makes local video recording and does not have an independent monitoring room. The core of hierarchical networking is "who can access who, where the video exists, and whether the bandwidth is enough".
| Networking Hierarchy | Typical Architecture | What is checked on the screen wall side | What conditions are not established |
|---|---|---|---|
| Head Office↔Branch | The head office monitoring center brings together the video of each branch; | Whether the head office can access the real-time video of the branch; | When the bandwidth from the head office to the branch is insufficient, the multi-channel simultaneous access will be stuck. |
| Branch↔Sub-branches/outlets | Branch monitoring center gathering area sub-branches and outlets video | Whether the branch can access the real-time video of the outlet; Whether the video can be accessed; Whether the alarm can be uploaded | When the uplink bandwidth of the network is insufficient, frames will be lost when multiple videos are uploaded at the same time. |
| Local outlets | Local NVR video recording of outlets, no independent monitoring room | Can the network alarm be uploaded to the branch? Local video storage time | When the network of the network is interrupted, the alarm cannot be uploaded and can only be recorded locally. |
| Networking with public security | According to the requirements of the Ministry of Public Security and the Banking and Insurance Regulatory Commission, the designated video and alarm will be pushed to the public security platform. | Whether the networking channel is in compliance; push scope and permission | Compliance isolation and approval are required between the financial private network and the public security network. |
The four-level platform is successfully cascaded through the bank's private network, which only shows that signaling and video streams can be exchanged between the platforms. Whether the screen wall can be accessed also depends on whether the decoder supports the encoding format of the link, whether the access rights of the screen wall are open, and whether the route of cross-level access passes through the correct platform. In the plan, "who has the right to transfer whom, access to several platforms, and the approximate delay" should be confirmed step by step, instead of writing "support level 4 networking" in general ".
4. alarm review three-level response: network alarm → branch review → head office confirmation → public security linkage
The processing process of bank alarm is different from that of hospital and community. After the network alarm, it is usually not the network itself, but "the branch monitoring center first reviews, the head office confirms, and then notifies the public security". The screen wall is responsible for the display tasks of "review" and "confirmation" in this process.
| Response link | by whom to operate | What the screen wall shows | Key points of verification |
|---|---|---|---|
| Network alarm trigger | Network alarm host/access control/ATM | Alarm network location, alarm type, time | Whether the alarm can be uploaded to the branch; whether the branch number and location are included |
| Branch Review | Branch monitoring center attendant | Alarm network video, peripheral picture, alarm type details | The response time of video retrieval; the picture can be identified; check whether the record is marked |
| Head Office Confirmation | Head office monitoring center (large/major alarm) | Branch review results, alarm network video, disposal recommendations | Whether the head office can see the branch review record; Confirm whether the process is traceable. |
| public security linkage | Branch/Head Office Security Department | Alarm push status, public security disposal status (e. g. open return) | Whether the push is successful; whether the status return is visible |
In industry practice, the large bank monitoring screen can realize the unified control of multiple systems such as network monitoring, integrated monitoring, alarm, entrance guard, intercom, vehicle-mounted, GIS, etc. of business outlets, self-service banks, vaults, wealth management offices, sub-branches, branches and head offices. It should be confirmed in the plan: who configures the process and authority of alarm review; Whether the screen wall side supports the distinction between "branch review window" and "head office confirmation window"; Check and confirm whether the operation is marked.
The number of 5. screens is reverse: branches and head offices are the focus, and outlets usually do not have independent screen walls.
The bank monitoring screen wall is mainly located in the centralized monitoring center of the branch and the head office, and the branch itself usually only does local video recording, without an independent monitoring room. The number of screens is pushed back by "the number of outlets in the jurisdiction, the alarm review window, the ATM vault monitoring, and the cash transport vehicle monitoring.
The head office screen wall is summarized by national/provincial branches; The outlets usually do not have independent screen walls, but only do local video recording and alarm uploading.
Take a 55-inch single screen as an example, a branch monitoring center that manages 20-30 outlets, with a total of 12 screens of 4 × 3, is a common starting point: 4-6 screens for network round-robin (grouped by region),2 screens for alarm review, 2 screens for ATM/vault monitoring, 1 screen for cash truck GIS, and 1 screen for consultation. The head office monitoring center may be larger, 4 × 4 or more, configured according to the number of branches and alarm volume. Branches and outlets usually do not have independent screen walls.
6. site conditions and installation: special requirements for branch monitoring centres
| Requirement | Impact on the screen wall | Coping strategies |
|---|---|---|
| financial private network access | Connection position of screen wall and private network equipment | The decoder is connected to the nearest private network; the screen wall is isolated from the office network. |
| UPS and Generator | Monitoring center cannot be powered off | Connect the screen wall to the UPS circuit; confirm the backup time |
| Separation of monitoring center and computer room | Long distance of signal cable | Fiber or HDBaseT transmission |
| 7 × 24 operation | The screen body needs to run stably for a long time. | Industrial grade panel; heat dissipation design; spare parts reservation |
| Security and confidentiality | Monitoring center access control | Security requirements shall be considered for the installation position of the screen wall; operation marks shall be left. |
7. budget trade-offs and source manufacturer value
The bank project budget is usually controlled jointly by the security department and the science and technology department, and the order of choice is recommended:First, ensure the reliability of alarm review (branches can quickly review and head office can confirm), then ensure the access of ATM vault and cash transport vehicle monitoring, then ensure the bandwidth and authority of hierarchical networking, and finally consider the patchwork upgrade and consultation function. Don't sacrifice alarm review or graded networking for the sake of "patchwork 0.1mm"-the former is a visual bonus and the latter is the bottom line of bank security.
Qunmao Display Technology (Qtenboard)AsLCD splicing screen China source manufacturersThe value in the bank video surveillance project is reflected in three specific links. First,Combination of patchwork and size as per monitoring center conditions: The branch monitoring center may need 55 inch 1.8mm patchwork to make 4 × 3, the head office may need 55 inch 0.88mm to make 4 × 4, and the source manufacturer can combine according to the project requirements in the full gear range of 43-75 inch, 0.88mm to 8mm. Qtenboard 0.88mm ultra-narrow edge products adopt LG and BOE's Class A industrial panels and support 24/7 operation. Each one has undergone 48-hour aging test and is suitable for the long-term operation of bank monitoring centers. Second,Non-standard installation and confidential adaptation: The wall conditions, cabinet depth and maintenance space of the bank monitoring center are different. Floor cabinets, front maintenance brackets or non-standard reinforcement schemes need to be customized according to the site. The supporting capacity of source manufacturers is more controllable than that of traders. Third,Long-term spare parts and remote management: The service life of the bank security system is long, and the replacement unit needs the same model panel after five years; the Qtenboard cloud CMS supports remote equipment monitoring and batch management, and the supply of spare parts is more reliable than that of traders. Qtenboard support OEM/ODM cooperation mode, integrators can customize the configuration according to the needs of bank projects.
8. drill acceptance: run "network alarm → branch review → head office confirmation → public security linkage"
| Phase | Exercise Action | Key points of verification |
|---|---|---|
| Network alarm | Simulate ATM abnormality or access control alarm trigger in a certain network | The alarm is uploaded to the branch; the screen wall pops up the location and type of the alarm network point. |
| Branch Review | The branch attendant calls up the video of the alarm network and the surrounding pictures. | Video retrieval response time; The picture can be identified; Check the record and leave marks. |
| Head Office Confirmation | The head office reviews the results of the branch review and confirms the disposal. | The head office can see the review records; the confirmation process can be traced back. |
| Vault double rule | Simulate the opening of the vault door and verify the double access record | Screen wall displays double information and video; single entry triggers alarm |
| Cash transport vehicle monitoring | Access to cash truck GPS location and on-board video | GIS display position; vehicle video can be accessed; abnormal alarm pops up |
| public security linkage | Confirm the alarm and push it to the public security platform | Push Status Visible; Disposition Status (e. g. Open Backway) Visible |
| Restore | Release the alarm and restore the daily layout | The layout returns to the standard state; no pop-up window remains |
9. common mistakes
- Myth #1: Copying hospital or community programs. The core of the bank is hierarchical networking, ATM vault double rule, cash transport vehicle monitoring and three-level alarm review, not doctor-patient disputes, fire linkage or access control parking perimeter. The screen wall position, linkage logic and permission design are different.
- Myth 2: The network is also equipped with a large screen wall. Bank outlets usually do not have independent monitoring rooms, only local video recording and alarm uploading. The screen wall is mainly located in the centralized monitoring center of the branch and the head office.
- Myth 3: Look at the vault video casually. The vault and the banknote-adding room involve financial security, video and access records should be strictly managed, and the double rule must be reflected on the screen.
- Misunderstanding 4: The alarm is only pushed to the network. Bank alarm is usually "branch → branch → head office → public security" three-level response, the screen wall should support the branch review and head office confirmation of the distinction.
- Myth 5: Ignoring the mobile target access of the armored vehicle. The access logic of the cash transport vehicle GPS and on-board video is different from that of fixed monitoring, and the bandwidth and platform capabilities need to be verified separately.
- Myth 6: Think that the "source manufacturer" is just cheap. The conditions of the bank monitoring center are complex, and non-standard brackets, patchwork combinations and long-term spare parts are more important than unit prices. Verification of plant qualification and actual case during assessment.
10. FAQ
Bank outlets monitoring splicing screen generally a few pieces?
Screen walls are mainly located in branches and head offices. Branch monitoring centers are usually 4 x 3 with a total of 12 blocks (adjusted by the number of outlets in the jurisdiction), and the head office may be 4 x 4 or larger. The outlets usually do not have independent screen walls, but only do local video recording and alarm uploading. The number of screens is pushed back by "network round patrol alarm review ATM vault cash transport vehicle.
What is the difference between the bank and the hospital and community programs?
Core difference: the bank has a four-level structure of head office-branch-branch-branch, and the screen wall is mainly located in the branch and head office. The core business is alarm review, ATM banknote adding room and vault double rule, and cash transport vehicle monitoring. The alarm is a three-level response of "network → branch → head office → public security". The network goes through the financial private network, and the network with the public security needs compliance. Schemes cannot template each other.
How is the double rule in the vault and banknote room reflected on the screen?
When the vault door is opened, the screen wall shall display the name and photo of the current entry and exit personnel, the entry time, whether the two people are all present, and the access control opening record. When the time difference between single person entering or double person exceeds the regulation, the system will alarm and pop up on the screen wall. This relies on the double rule configuration and video association of the access control system, and the screen wall is responsible for presentation.
How to access the GPS and car video of the cash truck?
The on-board GPS and video are transmitted back to the branch/head office platform through the wireless network, and the screen wall displays the location of the cash transport vehicle on the GIS, and the on-board video can be accessed. Need to confirm: whether the on-board equipment supports real-time backhaul; Whether the branch/head office platform supports mobile target access; Whether the bandwidth for simultaneous backhaul of multiple vehicles is sufficient.
How to realize the three-level response of bank alarm review?
The network alarm is uploaded to the branch, and the branch attendant calls for video review. Major alarms are confirmed by the head office and then notified to the public security. The screen wall shall support the distinction between "branch review window" and "head office confirmation window", leaving marks for review and confirmation operations. The process and authority are configured by the security department, and the screen wall is responsible for presentation.
What is the use of source manufacturers for bank monitoring projects?
Qunmao Display Technology, as a source manufacturer of LCD splicing screens in China, can combine splicing and sizes according to the conditions of the branch/head office monitoring center; non-standard brackets and confidential adaptations can be customized according to the site; long-term spare parts and remote management capabilities are more reliable than traders. During the assessment, factory qualifications, panel sources, and actual case studies are verified.
XI. Conclusion
The judgment chain of the bank branch monitoring splicing screen scheme can be compressed into six steps:
To distinguish the differences between banks and hospitals/communities → grasp the ATM vault double-person rule and cash transport vehicle monitoring → nuclear head office/branch/sub-branch hierarchical networking → design a three-level alarm review process → push back the number of screens according to the branch and the head office → use "network alarm → branch review → head office confirmation → public security linkage" to drill and accept.
The professionalism of the bank's screen wall is not "how big the screen is and how narrow the stitching is", but inThe network alarm can be uploaded to the branch, the branch can quickly check, the head office can confirm, the vault can open the door can see the double information and video, the cash transport vehicle position and on-board video can be read, the public security linkage status can be seen, and the same type of spare parts can be found in the replacement unit after five years.. A bank is not a hospital or a community, it is a combination of a four-level structure, a financial private network, a two-person rule, and a three-level response. Write these judgments into the graded networking table, the two-person rule linkage design, the alarm review process and the drill acceptance script, and then use them.Qunmao Display Technology LCD Splicing Screen China Source ManufacturerThe long-term operation of the bank is supported by the combination of stitching, non-standard supports and spare parts. The screen wall of the bank monitoring center is not "installed for inspection", but the operation interface on which the security department reviews the alarm and guards the safety of the network.
Four-level network fixed structure, double rule tube vault; Alarm review is divided into three levels, and the source manufacturer guarantees spare parts.
Current location:
Release date: 2026-10-26
Clicks:
Previous:
Return to list
Partner Links: