1. the installation logic of wall-mounted forms: which walls are suitable and which are not
Wall-mounted advertising machine is not applicable to all indoor scenes, and its installation premise determines the scope of adaptation. To judge whether a wall can be installed and whether it is worth installing, first look at three conditions.
- Wall bearing:Load-bearing wall and solid brick wall can be installed directly; light steel keel partition wall needs to confirm the reinforcement scheme, otherwise it is recommended to use vertical or hoisting.
- Power supply location:A power supply is required near the screen installation location, otherwise, it is necessary to evaluate whether to go through the open wire slot or lead from the nearest socket.
- Viewing distance:The wall-mounted machine is suitable for close viewing within 3 meters. If it exceeds this distance, either increase the size or switch to a higher brightness lifting scheme.
Suitable points include elevator hall, corridor, waiting area, back wall of cash register, outside wall of classroom and above government affairs window. Unsuitable points include the center of the lobby, the entrance drainage of the store, the temporary booth and the middle of the passage, which are more suitable for vertical or hoisting.
Put the common pain points of the B side into this logic, and it is clear that the paper notification is slow to update and the manual replacement cost is high. Vertical machines occupy passages, narrow corridors and front typhoons are not applicable; The contents of multiple stores and multiple floors are not uniform and lack remote management. Public scenes need emergency broadcast, time-sharing broadcast and multi-language prompt. The wall-mounted unit addressesFixed point, high-frequency update, unified managementThe problem is that not all propaganda scenes are suitable.
2. five types of core indoor commercial scene dismantling
The following is an explanation according to the specific wall position. Each type of scene answers the same question: what was originally placed on this wall, what changes have taken place in the information transmission mode after it was replaced by a wall-mounted machine, and what should be paid attention to when purchasing.
2.1 enterprise office and park: elevator hall, conference room entrance, staff passage
- Elevator Hall Wall:The original fire chart, watch list and notice sticker were posted. The wall-mounted machine turns passive stickers into active information that is caroused by time period, and employees can see what they should see every time they pass.
- Meeting room door wall:Show meeting schedule, temporary change, idle status. The calendar system can be docked to directly display the current occupancy or idle time, and employees do not need to push the door to confirm.
- Wall of staff channel:Security tips, internal notification, KPI publicity, suitable for medium information density, update frequency stability of the content.
- Selection Notes:The viewing distance of the elevator hall is 2 to 3 meters, usually 32 to 43 inches. The horizontal space at the entrance of the conference room is limited, usually 21.5 to 32 inches, with optional touch control.
2.2 mall retail and chain stores: cashier back wall, shelf end, outside fitting room
- Cashier back wall:When customers queue up, the line of sight stays naturally, which is suitable for pushing up gross profit commodities, member information and activity forecast. The brand recognition stage has passed, and this point requires transformation rather than image.
- Shelf End Wall:Size is limited by shelf spacing, usually 21.5 to 32 inches; brightness needs to consider the effect of top light reflection on readability.
- Fitting Room Outer Wall:New product recommendation, collocation suggestion, member discount, customer stay longer, suitable for playing longer content.
- chain procurement key:It's not whether to install it or not, but whether the headquarters sends out the content or the stores can adjust locally.Store advertising machineWhether the CMS of supports partition authority determines whether the content stores locked by the headquarters can be changed and whether the store promotion positions can be released by themselves.
2.3 government affairs hall and community service center: above the window, waiting area, bulletin board wall
- Wall above window:Call information, current processing matters, material list. Viewing distance, commonly used 21.5 to 32 inches, brightness should not be too high, to avoid direct window staff.
- Waiting Area Walls:Policy interpretation, work flow, community notification. The content should be designed according to the waiting time, what can be read in 3 minutes and what can be read in 10 minutes, instead of stacking all the information together for carousel.
- Procurement hard conditions:The content can be checked and emergency broadcast ability. Whether emergency notification can be pushed directly without regular scheduling is a function often listed as a technical requirement in government project bidding.
2.4 hospitals and clinics: waiting areas, department corridors, pharmacy windows
- Waiting area wall:The core task is to manage wait perception. The call progress, expected waiting time and current number segment are updated in real time, which can relieve anxiety more than circulating health education videos.
- Department corridor walls:Department introduction, doctor scheduling, precautions before examination, replace the high-frequency oral explanation of the nurse station.
- pharmacy window wall:Drug taking process, medication tips, queuing information, reduce the window repeated inquiries.
- Selection of hard conditions:Mute operation, the screen surface can be wiped, support partition playback. Hospital environments have clear requirements for cleanliness and noise, and models with significant fan noise are not suitable for waiting areas.
2.5 training institutions and schools: outside the classroom, public corridor, inside the school gate
- Classroom exterior wall:The schedule of the day, temporary adjustment of classes and classroom usage status are updated frequently, usually changing every day or even every class.
- Public Corridor Wall:Enrollment information, results show, activity notice. Corridors are 32 to 43 inches narrow and 55 to 65 inches wide.
- Multi-campus needs:The mixed release mode of headquarters template plus campus variables is the ability to be confirmed by training institutions and chain schools when selecting CMS.
2.6 other expandable scenarios
- Hotel and Catering:Menus, events, meeting guidelines.
- Banks and Financial Institutions:Interest rates, product introductions, queuing guidelines.
- Gym, beauty salon:Curriculum, membership activities, brand content.
- real estate sales offices and exhibition hall:Real estate information, apartment display, brand video.
- Factory and Warehouse:Production kanban, safety publicity, training notice.
3. size and function selection recommendations for different scenarios
3.1 Selection Judgment Conditions
Do not directly copy the size comparison table, first confirm item by item according to the following six conditions, and then look at the reference interval.
- viewing distance determines the size of the lower limit:The farther the distance, the larger the screen is needed, otherwise the information cannot be read clearly.
- wall height determines the installation of the upper limit:Too high a mounting location will sacrifice readability, especially for text content.
- Content type determines horizontal and vertical screens:Notification, list and scheduling are suitable for vertical screen. Video and split screen are suitable for horizontal screen.
- The average daily operating time determines the heat dissipation scheme:Only start up during business hours and run continuously at 16/7 and 24/7, with different requirements for screen and heat dissipation.
- Network conditions determine the update method:Wi-Fi, wired network or offline U disk update, directly affect the CMS selection.
- Content Management permissions determine system configuration:Headquarters unified management or stores can be adjusted locally, decide whether to need partition authority function.
3.2 Scenario Reference Table
| Scene |
Typical point |
Typical size range |
Key functions |
Installation attention |
| Corporate office |
Door of elevator hall and meeting room |
21.5 to 43 inches |
Timing playback, split screen, calendar synchronization |
Confirm wall load bearing and routing |
| Mall Retail |
Cashier back wall, shelf end |
32 to 55 inches |
High brightness, split screen, partition permissions |
Considering top light reflection and shelf spacing |
| Government Community |
Above window, waiting area |
21.5 to 55 inches |
Multi-language, emergency broadcast, leaving marks |
Wired network is recommended, stability is preferred |
| Hospital clinic |
Waiting area, department corridor |
43 to 55 inches |
Mute, wipeable, partition playback |
Confirm cleaning requirements and operating time |
| Training School |
Outside the classroom, public corridor |
32 to 65 inches |
4K optional, USB plus network, multi-campus synchronization |
Check viewing distance and installation height |
The above is a typical reference interval, not a fixed standard. Actual dimensions are to be confirmed in conjunction with the site survey, particularly with regard to wall conditions, viewing distance and content type. Hospital and government affairs scenarios have additional requirements for running time and content, which can be referredIndoor commercial advertising machine operation instructions。
Five conditions that must be confirmed before 4. purchase
This is a unique pre-purchase condition for wall-mounted machines, not a general list. We will talk about the model and price after confirming one by one.
- Wall conditions:Is it a load-bearing wall or a light steel keel partition wall? Light steel keel needs to confirm the reinforcement scheme, or use hoisting and vertical type instead.
- Power supply location:Is there a power supply near the planned installation location of the screen? If not, it is to go through the open wire slot or lead from the nearest socket, which will affect the construction period and appearance.
- Network mode:Does each point need to be covered Wi-Fi or reserved for network access? In government affairs and hospital scenarios, it is usually recommended to be wired, and retail stores can be Wi-Fi.
- Content Management Permissions:Can the store change the brand content of the headquarters? What is the process of releasing the temporary promotion content of the store? This determines whether the CMS supports the partition authority.
- Runtime:Is it necessary to start up only during business hours, or do you need 16/7 or 24/7? The running time will directly affect the heat dissipation scheme and screen selection, and if it cannot be confirmed, it will lead to an increase in the later repair rate.
5. landing effect and operational value
Do not write a specific percentage, only describe the changes in the mechanism, so that it is closer to the real project situation, but also facilitate the internal description of the procurement direction.
- Remote publishing replaces manual replacement:From printing and posting every week at each point to publishing once in the background, designated stores or regions are updated synchronously.
- Group management replaces station-by-station operation:One hundred stores adjust the promotion content, do not need to operate store by store, according to the city, store type or floor group distribution.
- Timing and Interludes Replace Temporary Changes:Regular content is automatically rotated according to the schedule, and emergency notifications can be inserted without manual switching on site.
- Brand consistency enhancement:The brand specifications and multilingual content of the headquarters are consistent at all points,Enterprise Publicity ScreenThe information is no longer dependent on the stores to understand.
- Gradually scalable:From a single-store pilot to a chain or campus-level deployment, the content management approach can transition smoothly.
6. Scene Adaptation Scheme Recommendation: Cats Wall Hanging Series
According to the actual product line corresponding to the scene, do not do forced sub-series.
- 10.1 to 55 inches, 2K:It is suitable for near viewing distance points such as the entrance of the conference room, the back wall of the cash register, the outside wall of the classroom, and the above of the government affairs window. The size covers the range of 21.5 to 43 inches.
- 32 to 98 inches, 4K:Suitable for hospital waiting area, government waiting area, store shelf end and other points that need larger picture or higher definition.
- Support horizontal and vertical screen switching, Android system, USB and network dual play mode.
- Support OEM and ODM:LOGO, boot animation, pre-installed software, packaging, manual customization.
Specific model, size and interface information can be viewedIndoor wall hanging digital signage product page。
7. four types of indoor commercial landing cases
The following cases cover typical locations such as corporate offices, retail chains, government halls, and hospital waiting, illustrating the configuration logic and operational changes under different wall conditions.
7.1 enterprise office park: elevator hall and meeting room entrance
Point Condition
- The wall of the elevator hall is a load-bearing wall, and the power supply is located on the right side of the wall, with a viewing distance of about 2.5 meters.
- The horizontal space at the entrance of the conference room is about 60cm, and the original A4 paper schedule is on.
Configuration Scenario
- The elevator hall is of 43-inch wall-mounted type, with horizontal screen installation and wired network access.
- The 21.5-inch wall-mounted machine is selected at the entrance of the conference room, with vertical screen installation and docking with the conference calendar system.
Implementation effect
Elevator hall notice changed from administrative daily printing and posting to background scheduling and playing; The free and occupied status is displayed in real time at the door of the conference room, and employees do not need to push the door to confirm.
7.2 retail chain stores: cashier back wall and shelf end
Point Condition
- The back wall of the cashier is about 1.6 meters wide and has a light band at the top. There is a certain top light reflection.
- Shelf end wall spacing of about 80cm, customer stay time is short.
Configuration Scenario
- The cashier rear wall is a 43-inch model with high brightness mode and horizontal screen installation.
- The end of the shelf is of a 21.5-inch model, installed on a vertical screen, and recommended for playing single items.
- Chain stores adopt a zoning authority scheme, headquarters content lock, stores can adjust the local promotion position.
Implementation effect
The headquarters will issue one time, and the designated cities or stores will be updated synchronously. Temporary store activities do not need to be operated one by one. For specific management methods, please referMulti-store Content Management Description。
7.3 Government Service Centre: Above Window and Waiting Area
Point Condition
- The wall above the window is 2.4 meters high, the viewing distance is close, and the ambient light is bright.
- The wall of the waiting area is about 3 meters wide, and the calling information and policy interpretation shall be displayed at the same time.
Configuration Scenario
- The 32-inch model is selected above the window, with moderate brightness to avoid direct staff.
- The waiting area is a 55-inch model, and the call number, process and notification are played in different areas.
- Support multi-language carousel and emergency broadcast, and the content release can be checked.
Implementation effect
Call information and policy interpretation are broadcast in different areas, and emergency notifications can be pushed directly around the regular scheduling, thus reducing the pressure of on-site inquiries.
Waiting Area of 7.4 Hospital: Call Progress and Health Education
Point Condition
- The wall of the waiting area is about 4 meters wide and the installation height is 1.8 meters. The environment requires quiet.
- The surface of the screen shall be wiped to meet the hospital cleaning specifications.
Configuration Scenario
- The 43-inch mute model is selected, installed on the horizontal screen and connected to the calling system.
- The split screen displays the current number segment, estimated waiting time and health education content.
- The department corridor is equipped with 32-inch models, and the precautions before the inspection are played circularly.
Implementation effect
Patients judge the waiting time by calling progress to reduce repeated inquiries. The high-frequency oral explanation of the nurse station is changed to circular play, and the information transmission is more stable.
8. FAQ
What indoor scenes are suitable for conventional wall hanging advertising machines?
It is mainly suitable for fixed points such as corridors, elevator halls, waiting areas, cashier back walls, classroom exterior walls, and above government affairs windows where people flow through. The lobby center, store entrance drainage, temporary booths, etc. are more suitable for vertical or hoisting.
What wall conditions are required for installing a wall-mounted advertising display?
Load-bearing wall and solid brick wall can be installed directly; Light steel keel partition wall needs to confirm the reinforcement scheme, or use vertical and hoisting instead. The power supply is also required near the installation location, otherwise the wiring method will be evaluated.
Can a CMS manage multiple stores or multiple floors?
Yes, provided that the CMS supports group management and partition permissions. Headquarters can lock in brand content, and stores can only adjust local promotion positions, depending on system configuration.
Do wall-mounted advertising machines have to be connected to the Internet? Do you support U disk playback?
No networking is necessary. Support U disk, LAN and cloud CMS three ways, network conditions limited points can be updated with U disk, networking points suitable for remote release.
What is the difference between 16/7 and 24/7 operation? How?
16/7 is suitable for retail stores and office scenes that are open during business hours, and 24/7 is suitable for points that need to be displayed around the clock, such as hospitals and government affairs. The running time directly affects the heat dissipation scheme and screen selection, which should be confirmed before purchasing.
What are the special requirements for advertising machines in hospitals and government scenes?
Hospital scenes require silent operation, screen surface can be wiped, and partition playback is supported. Government affairs scenes require content marks to be checked and emergency broadcast capabilities. Wired networks are usually recommended to ensure stability.
Do you support OEM and ODM customization? How about MOQ, delivery date and warranty?
Support LOGO, boot animation, pre-installed software, packaging, instructions and other customization. MOQ, delivery date and warranty policy are confirmed according to the specific model and project scale, which can be obtained by contacting us directly.
What is the difference between indoor wall hanging advertising machine and outdoor advertising machine?
Indoor models mainly consider heat dissipation, mute and viewing distance, with moderate brightness; outdoor models need waterproof, dustproof, high brightness and wide temperature operation, and the protection level and structure are completely different and cannot be mixed.
Conventional wall-mounted advertising machine is suitable for indoor commercial points that need to save space, unified management and long-term stable operation. If you need to confirm the size, installation method and content management plan according to your site conditions, you can contact us directly for project suggestions and quotations.
Obtain project proposal and quotation